10kV composite jacket lightning arrester
Classification :
PRODUCT DETAILS
The 10kv composite jacket lightning arrester is a critical component in medium-voltage power systems, designed to protect electrical equipment from the damaging effects of lightning strikes and switching surges. Its unique construction combines advanced materials and engineering to deliver reliable performance in various operating environments.
At the core of this arrester is a set of high-quality zinc oxide varistors, which are known for their excellent nonlinear voltage-current characteristics. These varistors quickly conduct excess current away from the protected equipment when overvoltage occurs, clamping the voltage to a safe level and then returning to a high-resistance state once the threat has passed. This rapid response ensures minimal damage to transformers, switchgear, and other sensitive components in the 10kv network.
The composite jacket is a key feature that sets this arrester apart. Made from a durable silicone rubber material, it provides superior insulation properties while offering exceptional resistance to environmental factors such as UV radiation, moisture, and temperature fluctuations. Unlike traditional porcelain jackets, the composite material is lightweight and flexible, reducing the risk of breakage during installation or due to mechanical stress. This makes the arrester suitable for use in both indoor and outdoor applications, including harsh industrial settings and coastal areas with high humidity.
Installation and maintenance of the 10kv composite jacket lightning arrester are designed to be user-friendly. It comes with standard mounting hardware that allows for easy integration into existing power systems, whether pole-mounted or installed in switchgear cabinets. The arrester’s compact design saves space, making it ideal for installations where room is limited. Additionally, the composite jacket is non-porous, preventing the accumulation of dirt and debris that can compromise performance, thus reducing the need for frequent cleaning and inspections.
It is a device used to protect electrical equipment or electronic systems from high transient overvoltage hazards such as lightning overvoltage and operating overvoltage. Its core function is to protect equipment insulation and operation safety by limiting the overvoltage amplitude, discharging lightning current or operating overvoltage energy, and restoring the system voltage to normal levels.
Model | Rated voltage Ur | Continuous operation voltage Uc | DC reference voltage U1mA | Residual voltage under nominal discharge current | Square wave 2ms | ||
kV | kV | ≥kV | Steep wave impulse residual voltage kV≤ | Lightning impulse residual voltage kV≤ | Operation impulse residual voltage kV≤ | A≥ | |
YH5W-10/27 | 10 | 8 | 14.4 | 31 | 27 | 23 | 150 |
YH5W-17/45 | 17 | 13.6 | 25 | 51.8 | 45 | 38.3 | 150 |
YH10W-51/134 | 51 | 40.8 | 73 | 154 | 134 | 114 | 400/600 |
YH10W-84/221 | 84 | 67.2 | 121 | 254 | 221 | 188 | 600/800/1000 |
YH10W-90/235 | 90 | 72.5 | 130 | 270 | 235 | 201 | 600/800/1000 |
YH10W-96/250 | 96 | 75 | 140 | 288 | 250 | 213 | 600/800/1000 |
YH10W-100/260 | 100 | 78 | 145 | 291 | 260 | 221 | 600/800/1000 |
YH10W-102/266 | 102 | 79.6 | 148 | 297 | 266 | 226 | 600/800/1000 |
YH10W-108/281 | 108 | 84 | 157 | 315 | 281 | 239 | 600/800/1000 |
YH10W-200/520 | 200 | 156 | 290 | 582 | 520 | 442 | 800/1000 |
YH10W-204/532 | 204 | 159 | 296 | 594 | 532 | 452 | 800/1000 |
YH10W-216/562 | 216 | 168.5 | 314 | 630 | 562 | 478 | 800/1000 |
Type code:Y- indicates metal oxide arrester YH- indicates composite jacket metal oxide arrester.
Nominal discharge current:indicates the nominal discharge current of metal oxide arrester, which are 0.5 kA, 1.5 kA, 5 kA, 10 kA, and 20 kA.
Structural feature code:W – indicates no gap;C – indicates series gap;
Place of use:S – indicates applicable to distribution system;Z – indicates applicable to power station system;R – indicates applicable to protect parallel compensation capacitor;D – indicates applicable to protect motor;N – indicates applicable to protect the neutral point of transformer (or rotating motor);X – indicates applicable to protect the line side of substation;F – indicates enclosed switchgear (GIS).
Characteristic numerals:Rated voltage/residual voltage at nominal discharge current, unit: kV
Additional characteristic code:J – indicates that the neutral point of the system is effectively grounded;W – indicates a heavily polluted area;G – indicates a high altitude area.
Application
FACTORY WORKSHOP






CUSTOMER VISIT










CERTIFICATE

Green design product management system evaluation certificate

Energy Management System Certification Certificate Attachment

Green Power Application Management System Evaluation Certificate

Energy Management System Certification Certificate

Energy Management System Certification Certificate

Shandong Taikai Electric Power Co., Ltd.---Green Factory
APPLICATION FIELD

Application

Application

Application

Application
FAQ

How can we guarantee quality?


How long is your delivery time?


Can we visit your factory?


About the product price?


Can you arrange the shipment?


Can you provide sample?

RELATED PRODUCTS
GET A FREE QUOTE